Visual fatigue of VDT operation under different illumination conditions in confined space
-
摘要: 受限空間內視覺疲勞是造成事故的主要原因之一。為探究有限空間內光照對視屏顯示終端(Visual display terminals,VDT)作業視覺疲勞的影響,選取24名作業人員,在搭建的受限空間平臺內進行VDT打字作業1 h,在50~700 lx范圍內設置7個光照梯度使用眼動儀采集瞳孔直徑數據。將采集數據進行歸一化和降噪處理。實驗結果表明,隨著照度增大,瞳孔直徑總體呈減小趨勢,且瞳孔?照度關系符合冪函數關系;照度400,550和700 lx環境下瞳孔直徑變化率在?12%~8%之間浮動,且隨著光照強度的增強,作業人員視覺疲勞發生的程度增加;在低照度50,100和200 lx環境下,瞳孔直徑變化率在?8%~4%之間浮動,且隨著強度的減弱,作業人員視覺疲勞發生的程度也會增加。本研究提出使用窗口化的瞳孔直徑標準差σ判斷視覺疲勞出現時間,低照度下的σ峰值出現時間早于高照度下σ峰值出現的時刻,300 lx照度下σ峰值出現的時刻最晚,50~300 lx弱光照下對視覺造成的疲勞程度大于300~700 lx強光照下造成的疲勞。Abstract: Using eyes with high concentration for long periods can cause visual fatigue. With the continuous development and progression of modern electronic devices, screens have become an integral part of many aspects of life. Watching a screen for a long time can cause extreme eye fatigue and accidents. A wireless monitoring system including multiple communication platforms is a new means of monitoring in confined spaces, which requires people to perform visual display terminal (VDT) operations in common operating places such as dispatch rooms, cabins, and shipyards. Visual fatigue in a confined space is one of the main causes of accidents. To explore the effect of lighting in a limited space on visual fatigue of VDT, 24 operators were selected to perform VDT typing in a confined space platform for 1 h, and seven light gradients were set within the range of 50–700 lx to collect pupil diameter data using an eye tracker. The collected data were normalized to reduce noise. Experimental results show that with an increase in illuminance, the pupil diameter generally decreases and the pupil–illuminance relationship conforms to the power function relationship. In high-illumination environments (400, 550, and 700 lx), the pupil diameter change rate fluctuates in the ?12%–8% range, and with the increase in light intensity, the degree of visual fatigue of workers increases. Under low-illumination environments (50, 100, and 200 lx), the pupil diameter change rate fluctuates in the range of ?8%?4%, and the degree of visual fatigue of the workers also increases with decreased intensity. This study proposes to use the windowed pupil diameter standard deviation, σ, to determine the time of visual fatigue. The peak value of σ under low illumination is earlier than that under high illumination; the peak value of σ under 300-lx illumination is the latest, weak illumination. The fatigue degree of vision caused by 50?300 lx is greater than that caused by strong illumination of 300?700 lx.
-
Key words:
- confined space /
- safety management /
- visual fatigue /
- visual display terminal task /
- pupil diameter
-
表 1 受試者參數
Table 1. Subject parameters
Age Height/cm Weight/kg Vision 21.6±1.8 170.9±7.0 61.9±11.5 4.7±0.3 表 2 不同函數擬合結果
Table 2. Fitting results of different functions
Fitting No. Equations Parameter values Adjustment coefficient, R2 Correlation 1 y=ax+b a=?000359; b=5.3027 0.8775 Pearson correlation coefficient ?0.094 2 y=ax2+bx+c a=4.72493×10?6; b=?0.0065; c=5.51167 0.7732 Sum of squared residuals: 0.7732 3 y=a+bxc a=6.0948; b=0.250; c=0.374 0.9856 Sum of squared residuals: 0.0097 4 $y = {{\rm{e}}^{a + bx + c{x^2}}}$ a=1.71; b=?0.00143; c=9.57×10?7 0.9364 Sum of squared residuals: 0.0557 表 3 σ峰值出現時刻
Table 3. Time of appearance of σ peak
min 50 lx 100 lx 200 lx 300 lx 400 lx 550 lx 750 lx 32 45 51 58 55 50 42 259luxu-164 -
參考文獻
[1] Ji L. Influence factors and cause analysis of working accidents in confined space. Min Saf Environ Prot, 2017, 44(6): 92 doi: 10.3969/j.issn.1008-4495.2017.06.021紀磊. 受限空間作業事故的影響因素和原因分析. 礦業安全與環保, 2017, 44(6):92 doi: 10.3969/j.issn.1008-4495.2017.06.021 [2] Yuan Y C. Analysis of asphyxia accidents caused by occupational poisoning in China from 2001 to 2016. Chin J Public Health Eng, 2017, 16(2): 260袁義昌. 2001—2016年全國較大以上職業性中毒窒息事故分析. 中國衛生工程學, 2017, 16(2):260 [3] Xu N, Zhang L J, Tao G. Risk analysis and safety measures of working in confined space. J Saf Sci Technol, 2011, 7(10): 160許楠, 張禮敬, 陶剛. 受限空間作業危險性分析及安全防范措施. 中國安全生產科學技術, 2011, 7(10):160 [4] You B, Wu C, Wang M. Experimental study on the impact of high temperature to human in confined space of deep mines. J Saf Sci Technol, 2013, 9(11): 30游波, 吳超, 王敏. 深井受限空間高溫環境影響模擬試驗研究. 中國安全生產科學技術, 2013, 9(11):30 [5] Negre T. More eyes on the invisible danger in confined spaces [J/OL]. EHS Today(2016-03-04) [2020-05-25]. https://www.ehstoday.com/safety/article/21917403/more-eyes-on-the-invisible-danger-in-confined-spaces. [6] Raheem S S, Al-Hasanid A T. Comparative study of computer vision syndrome and smart devices among the employers and students in college of college of health and medical technique of university of Al-furat Al-awsat techniques. Kufa. J Univ Babylon, 2018, 26(8): 29 [7] Wang D L, Wang X Y, Song Y G, et al. Visual fatigue assessment based on multi-task learning. J Imag Sci Technol, 2019, 63(6): 60414-1 doi: 10.2352/J.ImagingSci.Technol.2019.63.6.060414 [8] Xu M W, Jin L Z, Yu L, et al. Effect of long-term bowing of the head on neck muscle fatigue. Chin J Eng, 2019, 41(11): 1493徐明偉, 金龍哲, 于露, 等. 長時間頸部前屈對頸部肌肉疲勞的影響. 工程科學學報, 2019, 41(11):1493 [9] Blascheck T, Kurzhals K, Raschke M, et al. Visualization of eye tracking data: A taxonomy and survey. Comput Graph Forum, 2017, 36(8): 260 doi: 10.1111/cgf.13079 [10] Lambooij M, Fortuin M, Heynderickx I, et al. Visual discomfort and visual fatigue of stereoscopic displays: A review. J Imag Sci Technol, 2009, 53(3): 30201-1 [11] Sun L B. Rapid Detection Method of CFF and Its Application in Controller Fatigue Assessment [Dissertation]. Tianjin: Civil Aviation University of China, 2018孫立斌. 閃光融合臨界頻率快速檢測方法及在管制員疲勞評估中的應用[學位論文]. 天津: 中國民航大學, 2018 [12] Salobrar-García E, Ramírez A I, de Hoz R, et al. The impact of the eye in dementia: the eye and its role in diagnosis and follow-up // Update on Dementia, 2016: 379 [13] Guo M Z, Li S W. Driving fatigue quantification based on driver’s reaction time. J Jilin Univ Eng Technol Ed, 2020, 50(3): 951郭夢竹, 李世武. 基于駕駛員反應時間的駕駛疲勞量化. 吉林大學學報: 工學版, 2020, 50(3):951 [14] Rüsseler J, Münte T F, Wiswede D. On the influence of informational content and key-response effect mapping on implicit learning and error monitoring in the serial reaction time (SRT) task. Exp Brain Res, 2018, 236(1): 259 doi: 10.1007/s00221-017-5124-z [15] Chen C X, Wang J, Li K, et al. Assessment visual fatigue of watching 3DTV using EEG power spectral parameters. Displays, 2014, 35(5): 266 doi: 10.1016/j.displa.2014.10.001 [16] Yue K, Wang D L. EEG-based 3D visual fatigue evaluation using CNN. Electronics, 2019, 8(11): 1208 doi: 10.3390/electronics8111208 [17] Zou B C, Liu Y, Guo M, et al. EEG-based assessment of stereoscopic 3D visual fatigue caused by vergence-accommodation conflict. J Display Technol, 2015, 11(12): 1076 doi: 10.1109/JDT.2015.2451087 [18] Tian H J, Guan T, Cai M P, et al. Research on evaluation model of VDT visual comfort based on pupil diameter. Prog Laser Optoelectron, 2020, 57(15): 153301 doi: 10.3788/LOP57.153301田會娟, 關濤, 蔡敏鵬, 等. 基于瞳孔直徑的VDT視覺舒適度評價方法研究. 激光與光電子學進展, 2020, 57(15):153301 doi: 10.3788/LOP57.153301 [19] Wang C Y, Tian Y X, Jia H B. Driving fatigue detection based on feature fusion of information entropy. J Comput Methods Sci Eng, 2018, 18(4): 977 [20] Koo B Y, Jang M H, Kim Y C, et al. Changes in the subjective fatigue and pupil diameters induced by watching LED TVs. Optik, 2018, 164: 701 doi: 10.1016/j.ijleo.2018.03.077 [21] Lin Y T, Lin P H, Hwang S L, et al. Ergonomic evaluation of electronic paper: Influences of anti-reflection surface treatment, illumination, and curvature on legibility and visual fatigue. J Soc Inform Display, 2008, 16(1): 91 doi: 10.1889/1.2835042 [22] Li J, Wang Z, Qin Y R, et al. Study on the influence of an underground low-light environment on human safety behavior. Int J Occup Saf Ergon, https://doi.org/10.1080/10803548.2020.1784586 [23] Mashkoori A R, Asadi S, Yari A R, et al. Association between local illumination and visual fatigue among the research and development staffs of industry. Int Arch Health Sci, 2016, 3(4): 157 [24] Thomas M M, Lamb T D. Light adaptation and dark adaptation of human rod photoreceptors measured from the a-wave of the electroretinogram. J Physiol, 1999, 518(2): 479 doi: 10.1111/j.1469-7793.1999.0479p.x [25] Lin C, Zhao H J, Cao Y J. Improved color opponent contour detection model based on dark and light adaptation. Autom Control Comput Sci, 2019, 53(6): 560 doi: 10.3103/S0146411619060075 [26] Tummeltshammer K, Feldman E C H, Amso D. Using pupil dilation, eye-blink rate, and the value of mother to investigate reward learning mechanisms in infancy. Dev Cognit Neurosci, 2019(36): 100608 [27] Schafer R W. What is a Savitzky-Golay filter? IEEE Signal Process Mag, 2011, 28(4): 111 doi: 10.1109/MSP.2011.941097 [28] Cai T J, Tang H. Overview of the least square fitting principle of Savitzky-Golay smoothing filter. Digital Commun, 2011, 38(1): 63 doi: 10.3969/j.issn.1001-3824.2011.01.017蔡天凈, 唐瀚. Savitzky-Golay平滑濾波器的最小二乘擬合原理綜述. 數字通信, 2011, 38(1):63 doi: 10.3969/j.issn.1001-3824.2011.01.017 [29] Iskander J, Attia M, Saleh K, et al. Exploring the effect of virtual depth on pupil diameter // 2019 IEEE International Conference on Systems, Man and Cybernetics (SMC). Bari, 2019: 1849 [30] Math?t S. Pupillometry: Psychology, physiology, and function. J Cognition, 2018, 1(1): 16 doi: 10.5334/joc.18 [31] Pfleging B, Fekety D K, Schmidt A, et al. A model relating pupil diameter to mental workload and lighting conditions // Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems. San Jose, 2016: 5776 [32] Binda P, Pereverzeva M, Murray S O. Pupil size reflects the focus of feature-based attention. J Neurophysiol, 2014, 112(12): 3046 doi: 10.1152/jn.00502.2014 [33] Xu M W, Jin L Z, Tian X H, et al. Research on visual fatigue of screen operation in confined space. J Saf Sci Technol, 2020, 16(7): 152徐明偉, 金龍哲, 田興華, 等. 受限空間屏幕作業視覺疲勞研究. 中國安全生產科學技術, 2020, 16(7):152 [34] Tseng V W S, Abdullah S, Costa J, et al. AlertnessScanner: what do your pupils tell about your alertness // Proceedings of the 20th International Conference on Human-Computer Interaction with Mobile Devices and Services. Barcelona 2018: 41 [35] Hepach R, Westermann G. Pupillometry in infancy research. J Cognit Dev, 2016, 17(3): 359 doi: 10.1080/15248372.2015.1135801 [36] Zhao M R, Gao H N, Wang W, et al. Study on the identification of irritability emotion based on the percentage change in pupil size // Proceedings of the 2020 2nd International Conference on Image, Video and Signal Processing. Singapore, 2020: 20 [37] Shen L L, Sun W P. Using EEG for assessment of stereoscopic visual fatigue caused by motion-in-depth. Chin J Eng, 2017, 39(9): 1421沈麗麗, 孫偉鵬. 立體深度運動引發的立體視覺疲勞的腦電評估. 工程科學學報, 2017, 39(9):1421 -