Aseismic performance of a full-scale model of a two-storied frame structure with dense grid of slender columns
-
摘要: 為研究細密柱框架結構體系的抗震性能,對一個兩層密細柱框架結構的足尺模型進行了擬靜力往復荷載實驗,給出了實驗結果;利用有限元計算軟件ABAQUS、SAP2000和PKPM對模型進行了推覆分析,并與實驗結果進行了對比,發現軟件分析所得的裂縫模式和塑性鉸位置均與實驗結果吻合;最后得出了該實驗模型的性能曲線,并對其在罕遇地震作用下的性能進行了評價.實驗結果表明,作為框架結構的一種,密細柱框架體系可以發揮良好的抗震性能.Abstract: In order to investigate the aseismie performance of a kind of newly developed frame structure with dense grid of slender concrete columns in walls, a quasi-static test under reciprocating lateral loads was conducted for a full-scale two-storied modal frame and the experimental results were introduced. As a comparative study, the static elastoplastic push-over analyses were performed using different softwares of ABAQUS, SAP2000 and PKPM. Compared with the experimental results, the analyzed FEM models exhibited the same crack propagation patterns in walls, and the plastic hinge points also coincided with the experimental results. Finally, a capacity spectrum was obtained to evaluate the aseismic performance of the experimental model; its aseismic performance under eight-degree rare earthquake was evaluated. It is concluded that the aseismic performance of the frame structure with dense grid of concrete columns is considerably good.
-
Key words:
- frame structure /
- pseudo-static /
- cyclic load /
- aseismic performance evaluation
-

計量
- 文章訪問數: 163
- HTML全文瀏覽量: 27
- PDF下載量: 4
- 被引次數: 0