摘要: 在常溫下,采用固體顆粒層進行過濾除塵的實驗研究,并對實驗結果進行分析,探索了過濾介質粒徑、過濾層厚度和過濾速度對除塵效率和床層壓力差的影響.根據實驗結果,確定了最佳的過濾介質粒徑、過濾層厚度和過濾速度.Abstract: Based on the experiment of dust removal in a granular layer at normal temperature and the analysis of the Based on the experiment of dust removal in a granular layer at normal temperature and the experimental results, the influence of filter particle diameter, layer thickness and filtration velocity on the dust removal efficiency was researched. The result gave the optimal filter particle diameter, layer thickness and filtration velocity.
-
Key words:
- dust removal /
- granular layer /
- dust removal efficiency /
- pressure difference
-