Hot Model Investigation on Endpoint Carbon Control in Converters by Exhaust Gas Information
-
摘要: 建立了轉爐內鋼液含碳量動態檢測的數學模型,并在50kg感應爐上進行了熱模擬試驗。結果表明:利用質譜儀連續分析爐氣成分迅速而準確;計算出的爐氣流量精度較高;利用數學模型定碳誤差為0.03%。產生誤差的原因是爐子容量小,噴濺等對鋼水損失影響大;在大生產條件下,因為爐量大,其它條件也較優越,預計氣相定碳精度可大大提高。Abstract: A dynamic mathematical model for determining carbon contents in a converters has been established and the experiment was carried out in a induction furnace with a capacity of 50kg.Results are as follows:Contiuous analysis of exhaust gas content in a furnace by mass-spectrometer is accurate and quick.Flowrate of exhaust gas is calculated with high precision.Carbon contents in molten steel is calculated by the mathematicial model with a tolerance from 0 to 0.055%,and the average error of 0.03% during the whole blow process.Splashing is one of the factors which affect the accuracy of model estimation.In a practical production,with a larger furnace capacity and better condition, precision of the carbon content estimation will be improved to a large extent.
-
Key words:
- mass-spectrometer /
- delay /
- exhaust gas /
- converter
-

計量
- 文章訪問數: 177
- HTML全文瀏覽量: 37
- PDF下載量: 7
- 被引次數: 0