A Method for Film Passivation Process Study and Its Application
-
摘要: 根據傳統擦傷電極試驗原理,自行設計了一套用于薄膜材料鈍化過程研究的裝置,由于它采用的是斷裂方式產生裸表面,因而克服了傳統擦傷方式裸表面逐漸暴露于介質的弱點,能直接測量到真實反映鈍化過程的電流衰減曲線。利用這套裝置對磁控濺射晶態與非晶態不銹鋼合金薄膜在3.5%NaCl溶液中的鈍化過程進行了比較研究,結果表明非晶薄膜的裸表面具有更高的反應活性及更快的鈍化膜形成速度。Abstract: A set of film fracture apparatus has been designed on the basis of traditional scratching electrode experiment theory.The advantage of the film fracture method for passivation process study consists in the simultaneous exposing of the bare surface into solution,therefore the accurtate current decay relationship resulting from the passivation can be measured.The passivation process in 3.5% NaCl solution of the magnetron-sputtered amorphous and crystalline stainless steel film have been studied by use of the apparatus. The results showed that the bare surface of the amorphous film exhibited a higher reactivity and a more rapid formation rate of passive layer compared with the crystalline film.
-
Key words:
- film /
- passivation /
- fracture /
- scratch
-

計量
- 文章訪問數: 4427
- HTML全文瀏覽量: 83
- PDF下載量: 6
- 被引次數: 0